DMX Digital Audio Satellite Receiver DR500 Specifikace

Procházejte online nebo si stáhněte Specifikace pro Přijímač DMX Digital Audio Satellite Receiver DR500. DMX Digital Audio Satellite Receiver DR500 Specifications Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 62
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Confidential Page 1
Field Operations Manual
Chapter One – Overview and Policies
Zobrazit stránku 0
1 2 3 4 5 6 ... 61 62

Shrnutí obsahu

Strany 1

Confidential Page 1 Field Operations Manual Chapter One – Overview and Policies

Strany 2 - Table of Contents

Confidential Page 10 Edited 10-01-2009 Communication - (continued) In communicating with the General Contractor/Site Supervisor, you, as the Su

Strany 3 - Confidentiality:

Confidential Page 11 Edited 10-01-2009Communication - (continued) In communicating and interfacing with the customer; you, as the Subcontractor

Strany 4 - Confidential Page 4

Confidential Page 12 Field Operations Manual Chapter Two Installation and Service Procedures

Strany 5 - Confidential Page 5

Confidential Page 13 Edited 6-17-2008 Installation and Service Dispatch Procedures Installation Work: When DMX has a new installation to be co

Strany 6 - Shipment Verification

Confidential Page 14 Edited 10-01-2009 Installation and Service Dispatch Procedures - (continued) Service Call Dispatch: When dispatching a serv

Strany 7 - Confidential Page 7

Confidential Page 15 Edited 10-01-2009Installation and Service Dispatch Procedures - (continued) Service Call Dispatch: The following procedure i

Strany 8 - Timeliness

Confidential Page 16 Edited 6-17-2008 Installation and National Service Dispatch Procedures - (continued) DMX National Accounts: DMX National

Strany 9

Confidential Page 17 Edited 10-01-2009 Installation Closeout Procedure When a DMX installation is complete, the Subcontractor must send the signe

Strany 10 - Communication

Confidential Page 18 Edited 10-01-2009 Field Service Call Closeout Procedure When a field service call is complete, the Subcontractor must call D

Strany 12 - Chapter Two

Confidential Page 2 Table of Contents CHAPTER ONE - OVERVIEW I. MISSION STATEMENT II. COMPLIANCE AND CONFIDENTIALITY III. INSTALLATION

Strany 13 - Confidential Page 13

Confidential Page 20 Field Service Call Close Out Procedures - (continued) If a service call is incomplete, requires a additional time, a return

Strany 14 - Confidential Page 14

Confidential Page 21 Edited 10-01-2009Returned Material Authorizations (RMA's) For DMX installations and service work, as the DMX Subcontr

Strany 15 - Confidential Page 15

Confidential Page 22 Field Operations Manual Chapter Three – Administration

Strany 16 - Confidential Page 16

Confidential Page 23 Edited 10-01-2009 I. Invoicing for Contracted Installations Invoices must be submitted to DMX in a timely manner, no later

Strany 17 - Confidential Page 17

Confidential Page 24 II. Invoicing for Field Service Work Invoices must be submitted to the DMX office shown on the Work Order in a timely man

Strany 18 - Confidential Page 18

Confidential Page 25 Field Operations Manual Chapter Four - Field Standards

Strany 19 - Confidential Page 19

Confidential Page 26 I. Field Installation Standards The following provides the details that are to be complied with for every installation. Ge

Strany 20 - Confidential Page 20

Confidential Page 27 Loudspeakers • All surfac

Strany 21 - Confidential Page 21

Confidential Page 28 Wiring  Unless specifica

Strany 22

Confidential Page 29 Wiring – (continued) • S

Strany 23 - Confidential Page 23

Confidential Page 3 Edited 6-17-2008Overview Mission Statement: DMX’s mission is to be the global leader in providing the finest commercial

Strany 24 - Confidential Page 24

Confidential Page 30 Splicing • Types of lines

Strany 25

Confidential Page 31 Terminations • All wires c

Strany 26 - Confidential Page 26

Confidential Page 32 Labeling • All equipment s

Strany 27 - Confidential Page 27

Confidential Page 33 Anchoring • All equipment,

Strany 28 - Confidential Page 28

Confidential Page 34 Equipment Placement • Al

Strany 29 - Confidential Page 29

Confidential Page 35 Equipment Racks/Assembly

Strany 30 - Confidential Page 30

Confidential Page 36 Electrical Make sure the e

Strany 31 - Confidential Page 31

Confidential Page 37 9/26/2010 Satellite • All d

Strany 32 - Confidential Page 32

Confidential Page 38 II. Testing Procedures The

Strany 33 - Confidential Page 33

Confidential Page 39 III. Equipment for Subcontr

Strany 34 - Confidential Page 34

Confidential Page 4 Edited 6-17-2008Installation and Service - Network Policies Current Information: It is the Subcontrac

Strany 35 - Confidential Page 35

Confidential Page 40 IV. DBS Field Standards 1. EQUIPMENT O CHANNEL MASTER DISH O RECIEVERS O REMOTES O TOOLS AND MISC. HARDWARE 2. STANDARD

Strany 36 - Confidential Page 36

Confidential Page 41 DR200, DR 500/501, DR1000 Receivers • Full CD Stereo quality • Mono, Stereo and Digital outputs • One hundred plus channel

Strany 37

Confidential Page 42 Tools & Misc. Hardware Compass Inclinometer Concrete blocks RG-6 Coax Cable F- Compression type connectors RG-6 compress

Strany 38 - II. Testing Procedures

Confidential Page 43 Standards  NEVER penetrate the roof!!!  Try to hide dish from street view  Always ground the dish.  Always use requir

Strany 39 - Confidential Page 39

Confidential Page 44 DBS System Overview Although the use of satellites, satellite dishes, and receivers may seem complex, the DMX/DBS service use

Strany 40 - IV. DBS Field Standards

Confidential Page 45 Once the DMX music programming is received at your location, your DR500/1 or DR200 Receiver and associated audio components ta

Strany 41 - Remote Controls

Confidential Page 46 Remote Control Units To select music channels remotely, you can use any DMX remote control unit. All remote control models ha

Strany 42 - Tools & Misc. Hardware

Confidential Page 47 Antenna Installation and Alignment Satellite Dish Installer: Ground the RF input cable to the building grounding system as

Strany 43 - Standards

Confidential Page 48 Connecting Multiple Receivers to One Antenna Multiple DR500/1 Receivers can be connected to one antenna. However, to avoid da

Strany 44 - DBS System Overview

Confidential Page 49 IV. Inspections DMX reserves the right to inspect all DMX jobs in progress or completed. DMX’s field inspections are intend

Strany 45 - Confidential Page 45

Confidential Page 5 Edited 09-23-2010Service and Installation - Subcontractor Responsibilities As a DMX Subcontractor, you are responsible for

Strany 46 - Remote Control Units

Confidential Page 50 Field Operations Manual Appendix

Strany 47

Field Standards - Appendix AAudio Connections

Strany 48 - Recommended Equipment

Field Standards - Appendix AAudio Connections -(continued)Note: This does not show strain reliefs, only connectivity.Strain reliefs must be used at

Strany 49 - IV. Inspections

Field Standards - Appendix BCoaxial CableSignal distance before degradation on coax:• RG59 baseband (video) 600’ broadband (RF) 50’• RG6 baseban

Strany 50 - Appendix

Field Standards - Appendix BCoaxial Cable - (continued)BNC: A three bladed rotary cutter should be used (measurements shown for thisparticular connec

Strany 51 - Audio Connections

Field Standards - Appendix CCable PullsLeave extra wire at the starting and termination points. With long termprofitability in mind, losing a few fee

Strany 52 - Audio Connections

Field Standards - Appendix CCable Pulls - (continued)The best place to run the cable is through the roof support structure. Do not leavethe wire layi

Strany 53 - Coaxial Cable

Field Standards - Appendix CCable Pulls - (continued)CABLE DRESSING:• Do not tie AC cables from equipment together. Tie each cable separatelywith jus

Strany 54 - Coaxial Cable

Field Standards - Appendix DMounting HardwareUse This Bolt reference chart when choosing hardware.

Strany 55 - Cable Pulls

Field Standards - Appendix EAnchor ChartUse this chart when choosing anchors.

Strany 56 - Cable Pulls

Confidential Page 6 Edited 10-01-2009Shipment Verification For all shipments, open and inspect all cartons immediately upon receipt. • Exami

Strany 57

Field Standards - Appendix EAnchor Chart - (continued)Use this chart to determine the size of the hole to drill for the anchor you choose.DIAMETER OF

Strany 58 - Mounting Hardware

awg18161412 awg222018 awg22 awg24 5502FE5506FE1585A6502FE6506FE1583AN/AN/A1901ABelden #Belden #Belden #Belden #Belden #5300FE 6300FE5502GE 65

Strany 59 - Anchor Chart

awgRG-6RG-11RG-6RG-6RG-11awgNon-PlenumRG-58PlenumRG-58awgRG-6RG-59RG-6RG-59awgNon-Plenum26Plenum25awgNon-Plenum26Plenum25awgNon-PlenumRG-59awgNon

Strany 60 - Anchor Chart

Confidential Page 7 Edited 09-23-2010Shipment Verification - (continued) In all cases of reported damage, place all damaged freight in a protect

Strany 61 - Appendix F - Core Cable

Confidential Page 8 Edited 6-17-2008Workmanship/Warranty Expectations As the Subcontractor, you will have agreed to: • Correct any problems wi

Strany 62 - (continued)

Confidential Page 9 Edited 10-01-2009Communication In working with DMX, you will have agreed to: Inform your DMX contact within 24 hours if an

Komentáře k této Příručce